Standards
Energy labelling - Compact fluorescent lamps and light emitting diode lamps - Requirements
This standard specifies the relevant test methods and a proposed energy efficiency label design for the following:
a) Self-ballasted compact fluorescent lamps (CFL) of voltages > 50 V;
b) Integrated light-emitting diode lamps (LEDi) for stable operations, intended for domestic and similar general lighting purposes, having a:
1) rated power up to 60 W;
2) rated voltage of > 50 V a.c up to 250 V a.c.
a) Self-ballasted compact fluorescent lamps (CFL) of voltages > 50 V;
b) Integrated light-emitting diode lamps (LEDi) for stable operations, intended for domestic and similar general lighting purposes, having a:
1) rated power up to 60 W;
2) rated voltage of > 50 V a.c up to 250 V a.c.
This standard does not apply to semi-integrated (LEDsi) and non-integrated (LEDni) light-emitting diode lamps.
GYS 577
-
2021
GYD 5,500
17 pages
Hand sanitizers – Alcohol-based hand sanitizers – specifications
This document specifies chemical and labelling requirements for alcohol based hand sanitizers.
This standard applies to over-the-counter alcohol-based hand sanitizers.
This standard does not apply to:
a) Non-alcohol based hand sanitizers;
b) medical-grade hand sanitizers;
hand sanitizers used for
surgical application
GYS 598
-
2024
GYD 5,500
20 pages
International Building Code
The scope of the International Building Code® (IBC®) includes all buildings except detached one- and two-family dwellings and townhouses up to three stories. For the most current adoptions details go to International Code Adoptions
The 2018 IBC contains many important changes such as:
- Accessory storage spaces of any size are now permitted to be classified as part of the occupancy to which they are accessory.
- New code sections have been introduced addressing medical gas systems and higher education laboratories.
- Use of fire walls to create separate buildings is now limited to only the determination of permissible types of construction based on allowable building area and height.
- Where an elevator hoistway door opens into a fire-resistance-rated corridor, the opening must be protected in a manner to address smoke intrusion into the hoistway.
- The occupant load factor for business uses has been revised to one occupant per 150 square feet.
- Live loads on decks and balconies increase the deck live load to one and one-half times the live load of the area served.
- The minimum lateral load that fire walls are required to resist is five pounds per square foot.
- Wind speed maps updated, including maps for the state of Hawaii. Terminology describing wind speeds has changed again with ultimate design wind speeds now called basic design wind speeds.
- Site soil coefficients now correspond to the newest generation of ground motion attenuation equations (seismic values).
- Five-foot tall wood trusses requiring permanent bracing must have a periodic special inspection to verify that the required bracing has been installed.
- New alternative fastener schedule for construction of mechanically laminated decking is added giving equivalent power-driven fasteners for the 20-penny nail.
- Solid sawn lumber header and girder spans for the exterior bearing walls reduce span lengths to allow #2 Southern Pine design values.
IBC 0
-
2018
GYD 0