Standards
These requirements cover wire binding screw terminals of receptacles and switches rated 15 or 20 A intended for use with solid conductor aluminum building wire, and that require direct connection of wiring conductor(s) to the binding head screw terminal(s) prior to insertion of the device in an outlet box.1.2 These performance requirements for wire binding screw terminals are in addition to the requirements for the products covered by the Standard for Attachment Plugs and Receptacles, UL 498, and the Standard for General-Use Snap Switches, UL 20.
This standard covers portable flexible lighting products with a maximum input voltage rating of 120volts to be used in accordance with the National Electrical Code, ANSI/NFPA 70. These products are provided with a power supply cord and are intended for outline and decorative lighting use.1.2 These requirements cover lighting products incorporating non-replaceable series and series/parallel connected lamps enclosed within a flexible polymeric tube or extrusion.1.3 These requirements also cover flexible lighting products used in light sculptures.1.4 These requirements do not cover lighting products with replaceable lamps.1.5 These requirements do not cover the temporary-use, seasonal decorative-lighting products and accessories with a maximum input voltage rating of 120 V that are covered by the Standard for Seasonal and Holiday Decorative Products, UL 588.
1.1 These requirements cover LED equipment that is an integral part of a luminaire or other lighting equipment and which operates in the visible light spectrum between 400 – 700 nm. These requirements also cover the component parts of light emitting diode (LED) equipment, including LED drivers, controllers, arrays, modules, and packages as defined within this standard.
1.1 This standard describes the apparatus, test methods, and formulas to be used in carrying out the tests and calculations required by wire and cable standards. 1.2 Specific acceptance requirements are found in individual product standards. 1.3 Where a test method indicates a “specified” test parameter or condition, the parameter or condition is found in the individual product standard.
Requirements contained in this Standard cover controls of the light-sensitive or presence-sensitive types, or both; for indoor or outdoor service; intended for the control of indoor or outdoor loads up to maximum of 20 A and maximum 347 V; intended for installations on 50 Hz or 60 HZ systems or DC upto 60 V (for US); and DC up to 42.4 V (for Canada); and intended to be installed in accordance with the National Electrical Code (NEC), NFPA 70, the Canadian Electrical Code (CE Code) Part I, CSA C22.2 No0, and NOM 001 SEDE.
1.1 These requirements cover power outlets, with or without integral mounting posts or pedestals, and power outlet fittings for use in accordance with the National Electrical Code, NFPA 70.
1.1 This standard covers latching or locking type PV connectors either as a free connector (separate entity) or as a fixed connector (panel or bulkhead type) and rated 1500 V ac or dc or less. These connectors are intended for use in wiring methods detailed in Part IV of Article 690 – Solar Photovoltaic Systems of the National Electrical Code, NFPA 70.1.2 This standard is intended for single polarity PV connectors suitable for use on insulated, stranded copper type USE-2 or Photovoltaic Wire (PV Wire) rated 90°C, 105°C, 125°C, or 150°C dry; 90°C wet;600, 1000, or 2000 V..
This specification covers two grades of kerosene suitable for use in critical kerosene burner applications: 1.1.1 No. 1-K—A special low-sulphur grade kerosene suitable for use in non-flue-connected kerosene burner appliances and for use in wick-fed illuminating lamps. 1.1.2 No. 2-K—A regular grade kerosene suitable for use in flue-connected burner appliances and for use in wick-fed illuminating lamps.
This specification is intended for use in purchasing, as a reference for industry and governmental standardization, and as a source of technical information.
This specification, unless otherwise provided by agreement between the purchaser and the supplier, prescribes the required properties of kerosene at the time and place of custody transfer.
The main text of this national standard contains a list of these parameters, their units and references to measurement standards. Informative annexes give examples of typical values for these parameters, with the main emphasis on health and safety. In defining the parameters governing composition, physical properties and trace constituents, consideration has also been given to existing natural gases to ensure their continuing viability.
The question of interchangeability is dealt with in Annex A (see Clause A.2).
Fuel meeting the requirements of this part of ISO 15403 should:
(a) provide for the safe operation of the vehicle and associated equipment needed for its fuelling and maintenance;
(b) protect the fuel system from the detrimental effects of corrosion, poisoning, and liquid or solid deposition;
(c) provide satisfactory vehicle performance under any and all conditions of climate and driving demands.
Some aspects of this part of ISO 15403 may also be applicable for the use of natural gas in stationary combustion engines.