Standards
1.1 This specification (see Note 1) covers grades of fuel oil intended for use in various types of fuel oil-burning equipment under various climatic and operating conditions. These grades are described as follows:
1.1.1 Grades No. 1 S5000, No. 1 S500, No. 1 S15, No. 2 S5000, No. 2 S500, and No. 2 S15 are middle distillate fuels for use in domestic and small industrial burners. Grades No. 1 S5000, No. 1 S500, and No. 1 S15 are particularly adapted to vaporizing type burners or where storage conditions require low pour point fuel.
1.1.2 Grades B6–B20 S5000, B6–B20 S500, and B6–B20 S15 are middle distillate fuel/biodiesel blends for use in domestic and small industrial burners.
1.1.3 Grades No. 4 (Light) and No. 4 are heavy distillate fuels or middle distillate/residual fuel blends used in commercial/industrial burners equipped for this viscosity range.
1.1.4 Grades No. 5 (Light), No. 5 (Heavy), and No. 6 are residual fuels of increasing viscosity and boiling range, used in industrial burners. Preheating is usually required for handling and proper atomization.
1.1 This specification covers those products commonly referred to as liquefied petroleum gases, consisting of propane, propene (propylene), butane, and mixtures of these materials. Four basic types of liquefied petroleum gases are provided to cover the common use applications.
1.2 This specification is applicable to products intended for use as domestic, commercial and industrial heating, and engine fuels.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.3.1 The non-SI unit ‘psig’ is the standard unit for footnote C of Table 1 because that unit of measurement is widely used in the North American industry.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
This standard establishes the minimum energy performance standards (MEPs) for refrigerating appliances and relevant test method to specify the energy label. It also specifies the energy label requirements.
— Energy efficiency ratio (EER);
— Coefficiency of peformance (COP).
1.1 These requirements cover the installation of lightning protection systems on all types of structures other than structures used for the production, handling, or storage of ammunition, explosives, flammable liquids or gases, and other explosive ingredients including dust.
1.2 These requirements apply to lightning protection systems that are complete and cover all parts of a structure. Partial systems are not covered by this standard.
1.3 These requirements shall not apply to adjacent structures.
1.4 Adjacent structures shall be considered separate structures.
1.5 Adjacent structures with lightning protection shall be considered part of the structure if the adjacent structure’s lightning protection system complies with this standard and is connected to the lightning protection system of the structure in accordance with Section 10.4.
1
.6 Walkways that are attached to a structure shall be considered part of that structure.
1.7 Free standing Walkways shall be considered an adjacent structure under the following conditions:
a) It is separated by a fire wall and conductive media that is shared by both facilities has an SPD in accordance with Section 13.
b) It is isolated by a distance of not less than six feet and conductive media that is shared by both facilities has an SPD in accordance with Section 13.
1.8 This standard does not cover lightning protection
for:
a) Electric transmission lines or open air distribution racks,
b) Outdoor substations or switch yards, and
c) Electric generators unenclosed by a building other enclosed structure.
1.9 Enclosed generators and conventional
building structures at or associated with generators or power plants,
etc. are covered.
1
.10 These requirements do not cover lightning protection components, which are covered by the Standard for Lightning Protection Components, UL 96.1.1 These requirements cover industrial control panels intended for general industrial use, operating from a voltage of 1000 volts or less. This equipment is intended for installation in ordinary locations, in accordance with the National Electrical Code, ANSI/NFPA 70, where the ambient temperature does not exceed 40°C (104°F) maximum.
This International Standard specifies requirements for metallic, non-metallic and composite cable ties and their associated fixing devices used for the management and support of wiring systems in electrical installations.
Cable ties and associated fixing devices may also be suitable for other applications and where so used, regard should be taken of any additional requirements.
This standard does not contain requirements that evaluate any electrical insulation properties of the cable tie or mechanical protection of the cables provided by the cable tie.
This standard does not consider the mechanical interface of a fixing device to a solid surface such as a wall or ceiling.
This British Standard specifies
requirements for sheets of factory-made machine-welded steel fabric for the
reinforcement of concrete, manufactured from ribbed bars conforming to BS
4449:2005, or manufactured from wire conforming to BS 4482 for wrapping fabrics
D49 and D98.
NOTE 1 Where the term “bar” is used in this standard, it includes bar or recoiled product conforming to BS 4449:2005. For clarity only. It can also include wire conforming to BS 4482 for wrapping fabrics only.
1.1 This standard applies to:
(a) a used motor vehicle that is offered or displayed for sale by a supplier, whether the supplier is acting as an agent for another person or through a motor vehicle trader or dealer;
(b) a supplier who is a party to, or acts as an agent for a party to, a contract for the sale of a used motor vehicle to which this standard applies; and
(c) a consumer information notice that should be provided by the supplier which discloses information about a motor vehicle.
1.2 This standard does not apply to:
(a) a used motor vehicle that is offered or displayed for sale by a supplier if it is offered or displayed for sale exclusively to other suppliers registered under the competent authority to provide such services or to suppliers who are licensees under the law of State to provide services such as car wreckers; and
(b) a moped, a trailer, a mobility device, a tractor or farm machinery or any vehicle of any class or description declared by the relevant authority to be a motor vehicle.