This standard specifies the conditions under which ready-mixed concrete shall be made and delivered, and the methods by which the purchaser can specify with his enquiry or order, the properties of the concrete required. It provides a specification for the production and supply of ready-mixed concrete. Methods of specifying ready-mixed concrete for nominal mixes, specified strength mixes and mixes for special purposes, to meet the requirements of standard codes of practice, are covered. It also gives guidance on the data to be provided by the purchaser when ordering ready-mixed concrete, the inspection facilities to be provided by the supplier and the appropriate tests. Routine tests which must be carried out by the supplier and those which are the responsibilities of the purchaser are also included. This standard does not cover the placing, compaction, curing or protection of the concrete after delivery, nor does it apply to materials for lean concrete or similar road care materials.
These requirements cover temporary-use, seasonal decorative-lighting products and accessories with a maximum input voltage rating of 120 V to be used in accordance with the National Electrical Code, ANSI/NFPA 70. Temporary-use is considered to be a period of installation and use not exceeding 90 days. 1.2 These requirements cover factory-assembled seasonal lighting strings with push-in, midget-screw, or miniature-screw lampholders connected in series for across-the-line use or with candelabra- or intermediate-screw lampholders connected in parallel for direct-connection use. These requirements also cover factory-assembled seasonal decorative outfits such as wreaths, stars, light sculptures, crosses, candles or candle sets without lamp shades, products in the shape of, or in resemblance to, Christmas trees with simulated branches and needles, products in the shape of, or in resemblance to, wreaths provided with simulated branches and needles, blow-molded figures or objects, animated figures, tree tops, controllers, tree stands, electric tree poles, and motorized decorative displays. These requirements cover products which are portable and not permanently connected to a power source.
This standard describes the requirements and operational parameters for electrical appliance protectors for use with equipment at normal voltage of 110V, 120V,220V, 240V and a current of up to including 40 A.
This standard specifies requirements for brewery products including beer, stout, shandy and malta; to be sold or traded in the CARICOM region.
It is not applicable to beverages that are not derived from cereals, sold under common names including the words "beer" and "ale".
EXAMPLE Ginger beer, ginger ale, root beer are not covered by this standard.
This British Standard specifies requirements for the construction dimensions and mechanical and electrical properties of non- armoured polyvinyl chloride (PVC) insulated cables for operation at voltages up to and including 450 V a.c. to earth and 750 V a.c between conductors, intended for electric power lighting and internal wiring.
This standard specifies the materials, profiles and dimensions of hot-dip
zinc coated corrugated steel sheets for general purposes.
This standard specifies the materials, profiles and dimensions of hot-dip zinc coated corrugated steel sheet for general purposes.
This standard specifies the requirements for zinc-coated, steel chain-link fence fabric (zinc-coated either before or after weaving) and poly (vinyl chloride) coated, zinc-coated steel chain-link fence fabric.
1.1 The requirements of this standard cover holders and connectors for electric lamps, including incandescent, fluorescent, and other electric-discharge-type lamps, rated as indicated in Clause 6, to be used in accordance with the Canadian Electrical Code (CEC), Part I, C22.1, and the National Electrical Code (NEC), ANSI/NFPA 70. 1.2 These requirements cover screw lampholders, including those intended to be mounted directly on an outlet-box, lampholders for special uses, lampholders for electric signs, and adapters that convert one lampholder size to another.
These requirements cover FITTINGS for use with cable and conduit intended for installation in accordance with the National Electrical Code, ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part I, CSA C22.1, and the Standard for Electrical Installations, NOM-001-SEDE. 1.2 These requirements cover CONDUIT LOCKNUTS, conduit BUSHINGS, metal stud BUSHINGS, CONDUIT BODIES, and entrance ELBOWS; FITTINGS for electrical metallic tubing, flexible metal conduit, intermediate metal conduit, liquid-tight flexible conduit, rigid metal conduit, and SERVICE-ENTRANCE HEADS; FITTINGS or box clamps referenced from other standards for armored cable, metal-clad cable, aluminum-sheathed cable, mineral-insulated cable, nonmetallic-sheathed cable, service-entrance cable, and tray cable, and submersible FITTINGS; FITTINGS for flexible cord, flexible nonmetallic and metallic tubing, INSULATING BUSHINGS, grips, reducing washers, and NIPPLES.