Standards
This Standard describes a test method for the determining of the resistance to separation of the upper from the outsole or to separate adjacent layers of the outsole or to cause tear failure of the upper or the sole is measures. It also defines conditions of aging that can be used for production control. It applies to all types of footwear (cementing, vulcanization, injection moulding, etc.) where the evaluation of sole adhesion on the upper is needed and where the upper is continuously assembles (closed shoe).
This document describes a test method for determining the resistance to separation of the upper from the outsole, for separating adjacent layers of the outsole or for causing tear failure of the upper or the sole. It also defines conditions of ageing that can be used for production control.
This document is applicable to all types of footwear (cementing, vulcanisation, injection moulding, etc.) where the evaluation of sole adhesion on the upper is needed and where the upper is continuously assembled (closed shoe).
NOTE 1 In all cases the objective is to test the bond strength nearest to the edge of the assembly.
NOTE 2 The test need not be carried out when the bond has been made by grindery (using, for example, nails or screws) or stitching.
This document specifies a method for the determination of the abrasion resistance for outsoles,
This document specifies three methods for determining the shape retention properties and compression strength of a doomed test specimen.
1.1 The requirements of this standard cover holders and connectors for electric lamps, including incandescent, fluorescent, and other electric-discharge-type lamps, rated as indicated in Clause 6, to be used in accordance with the Canadian Electrical Code (CEC), Part I, C22.1, and the National Electrical Code (NEC), ANSI/NFPA 70. 1.2 These requirements cover screw lampholders, including those intended to be mounted directly on an outlet-box, lampholders for special uses, lampholders for electric signs, and adapters that convert one lampholder size to another.
These requirements cover products which are molded of insulating material and are molded of insulating material and are intended to cover the outlet slots of receptacles having 1-15R and 5-15R configurations in accordance with Wiring Devices - Dimensional Specifications, ANSI/NEMA WD6.
This standard applies to pin and sleeve type plugs, receptacles, power inlets, and connectors, rated up to 800 amperes and up to 600 volts ac or dc, and which may include up to eight pilot contacts. These devices are intended to provide power from branch circuits, or are for direct connection to the branch circuit in accordance with the Canadian Electrical Code Part I, the National Electrical Code (NEC),ANSI/NFPA 70, and the Mexican Electrical Code, NOM 001 SEDE, using copper conductors, for use in either indoor or outdoor nonhazardous locations. In Canada, the terminals of a device intended to accommodate aluminum conductors also comply with CSA C22.2 No. 65.
This standard covers portable flexible lighting products with a maximum input voltage rating of 120volts to be used in accordance with the National Electrical Code, ANSI/NFPA 70. These products are provided with a power supply cord and are intended for outline and decorative lighting use.1.2 These requirements cover lighting products incorporating non-replaceable series and series/parallel connected lamps enclosed within a flexible polymeric tube or extrusion.1.3 These requirements also cover flexible lighting products used in light sculptures.1.4 These requirements do not cover lighting products with replaceable lamps.1.5 These requirements do not cover the temporary-use, seasonal decorative-lighting products and accessories with a maximum input voltage rating of 120 V that are covered by the Standard for Seasonal and Holiday Decorative Products, UL 588.
This part of IEC 61730 specifies and describes the fundamental construction requirements for photovoltaic (PV) modules in order to provide safe electrical and mechanical operation. Specific topics are provided to assess the prevention of electrical shock, fire hazards, and personal injury due to mechanical and environmental stresses. This part of IEC 61730 pertains to the particular requirements of construction. IEC 61730-2 defines the requirements for testing. This International Standard series lays down IEC requirements of terrestrial photovoltaic modules suitable for long-term operation in open-air climates. This standard is intended to apply to all terrestrial flat plate module materials such as crystalline silicon module types as well as thin-film modules. PV modules covered by this standard are limited to a maximum DC system voltage of 1 500 V.