Standards
This standard defines working positions and makes it possible to locate welds in space with reference to the horizontal reference plane (usually parallel to the workshop floor) by means of angles of slope and rotation which are independent from surrounding construction.
This standard gives recommendations on the serviceability of buildings against vibrations. It covers three recipients of vibrations: a) human occupancy in buildings and on pedestrian bridges; b) the contents of the building; c) the structure of the building. It applies to buildings, pedestrian bridges and walkways found within buildings or connecting them and does not include bridges that carry vehicular traffic, nor the design of foundations or supporting structures of machinery.
These requirements cover household motor-operated food preparing machines and
kitchen accessories such as knife sharpeners and can openers that are intended
to be operated for short-periods of time.
This Standard applies to self-contained household refrigerators and freezers designed to be installed and used in residential occupancies in accordance with the Canadian Electrical Code, Part 1, CSA Standard C22.1, and the National Electrical Code, ANSI/NFPA 70.
The requirements cover television equipment intended for household and commercial use on supply circuits in accordance with the National Electrical Code, NFPA 70.
This standards covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.
This standard covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80 C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code.. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.
This standard specifies requirements for hollow non-load-bearing concrete masonry units made from portland cement, water and mineral aggregates with or without the inclusion of other materials. It covers three weight classifications of the concrete masonry units: (a) Normal weight; (b) Medium weight; and (c) Light weight. It also covers the sampling and testing of hollow non-load-bearing concrete masonry units for compressive strength, absorption, weight, moisture content and dimensions. It does not cover blocks intended solely for decorative purposes.
This standard describes the requirements and operational parameters for electrical appliance protectors for use with equipment at normal voltage of 110V, 120V,220V, 240V and a current of up to including 40 A.
This British Standard specifies requirements for the construction dimensions and mechanical and electrical properties of non- armoured polyvinyl chloride (PVC) insulated cables for operation at voltages up to and including 450 V a.c. to earth and 750 V a.c between conductors, intended for electric power lighting and internal wiring.