This action of IEC 1241-2 specifies two last methods for determining the minimum ignition temperatures of dust. The methods are not suitable for use will having explosive properties.
This part IEC 61241 specifies general requirements for the design construction testing and marking of electrical apparatus by an recognized safeguard technique for use in areas where combustible dust may be present in quantities that could lead to a fire or explosion hazard.
This part of IEC 61300 describes a method to measure the angular rotational misalignment of the ferrule mating surface of angled end face connector and its design orientation angle with respect to its key.
This international standard a application to industrial high-frequency dialectic heating installations used for the purpose of thermal applications such as melting, drying, welding insect extermination, and gluing of partially conductive or non-conductive materials such as plastics wood rubber, textiles, glass ceramic paper bamboo or foodstuffs, in both normal and protective atmospheres, using for example inert gasses or vacuum.
This part of IEC 61326 specifies requirements for immunity and emissions regarding electromagnetic compatibility (EMC) for electrical equipment , operating from a supply or battery of less than 1 000 V a.c. or 1 500 V d.c. or from the circuit being measured, intended for professional , industrial-process, industrial -manufacturing and educational use, including equipment and computing devices for. - measurement and test, - control - laboratory use , accessories intended for use with the above (such as sample handling equipment.) intended to be used in industrial and non-industrial locations.
In addition to the scope of IEC 61326-1, this part of IEC 61326 specifies more detailed test configuration operational conditions and performance criteria for equipment with test and measurement circuits (both internal and or external to the equipment) that are not EMC protected for operational and or functional reasons, as specified by the manufactures.
In addition to the scope of IEC 61326-1 this part of IEC specifies more details test configurations operational conditions and performance criteria for equipment which is - use for testing measuring or monitoring of protective measure in low-voltage distribution systems and . - powered by battery and or from the circuit measured and portable.
In addition to the scope of International standard IEC 61326-1, this part specifies minimum requirements for immunity and emission regarding electromagnetic compatibility for in vitro diagnostic medical equipment equipment, taking into account the particularities and specific aspects of this electric equipment and their electromagnetic environment.
This part of IEC 61347 specifies particular safely requirements for electronic step-down convertors for use on d.c. supplies up to 250 V or a.c. supplies up to 1000 V at 50 Hz or 60 Hz and rated output voltage ~ 50 /2 unsmoothed d.c. between conductors or between any conductor and earth associated with tungsten- halogen lamps as specified in IEC 60357 and other filament lamps .
This part of IEC 61400 specifies essential design requirements to ensure the engineering integrity of wind turbines. Its purpose is to provides an appropriate level of protection against damage from all hazards during the planned lifetime.,