This collateral standard applies to medical diagnostic equipment and to sub-assemblies of such equipment. The object of this collateral standard to establish general requirements for protection against ionizing radiation in medical diagnostic X-ray equipment , in order that the dose equivalent to the patient the operator and other staff can be kept as low as reasonably achievable.
This collateral standard applies to the safety of medical electrical equipment and medical electrical system incorporating programmable electrical subsystems (press ), hereinafter referred to as programmable electrical medical systems (PERMS).
This collateral standard specifies requirements for a process to analyses , design, verify and validate the usability , as it relates of medical electrical equipment , hereinafter referred to as equipment, This standard normal use and use errors but excludes abnormal use.
This collateral standard specifies requirements for alarm systems and alarm signals in medical electrical equipment and medical electrical systems.
This clause of the General standard applies except as follows : This particular standard specifies requirements for the safety , including essential performance, of recording and analyzing single channel and multichannel electrocardiographs as defined in 2, 101, 2, 111, 2, 117, 2,123, 2, 126, hereinafter referred to as equipment. The equipment may be attended or unattended.
This clause of part 1 is applicable except as follows : These particular requirements apply to electrical rang hood ( including their accessories and their component parts) for household and similar use. By similar use is understood the use in similar conditions as in households, for example in inns, coffee- houses, tea-rooms.
This standard is applicable to mains-powered or battery -powered information technology equipment, including electrical business equipment and associated equipment, with a rated voltage not exceeding 600 V.
This standard specifies the safety and interchangeability requirements, together with the test methods and conditions, required to show compliance of tubular florescent and other gas discharge lamps with integrated means for controlling starting and stables operation ( self ballasted) , Intended for domestic and similar general lighting purposes, having a rated wattage up to 60 W. - a rated voltage of 100 V to 250 V. Edison screw or bayonet caps. The requirements of this standard testing or batch testing are under consideration.
This standard specifies the performance requirements together with the test methods and conditions required to show compliance of tubular fluorescent and other gas-discharge lamps with integrated means for controlling starting and stable operation (self-ballasted lamps) intended for domestic and similar general lighting purposes. a rated wattage up to 60 W. -a rated voltage of 100 V to 250 V. - Edison screw or bayonet caps.
This part of IEC 61097 specifies the minimum performance requirements technical characteristics and type-testing requirements for narrowband telegraph equipment for the reception of navigational and meteorological information as required by regulation IV17.1.4 of the 1988 amendments to the 1974 International convention for safety of life at sea (SOLAS) and which the requirement in the standard takes precedence.