Standards
This CARICOM Regional Standard specifies requirements and methods of test for pasta products made from semolina, durum flour, wheat flour, farina flour or any suitable wheat flour. This standard is applicable to pasta classified as macaroni, spaghetti, vermicelli, noodles and egg noodles. This standard also applies to pasta products used in preparing other foods or included in packages of ingredients that are prepared for retail sale. EXAMPLE Pasta used in canned soups, soup mixes, macaroni and cheese dinners. This CARICOM Regional Standard is not applicable to Asian/Oriental style noodles including chowmein or chaomein and to other food in forms resembling pasta products made from rice, beans or cereals other than wheat.
These requirements cover wire binding screw terminals of receptacles and switches rated 15 or 20 A intended for use with solid conductor aluminum building wire, and that require direct connection of wiring conductor(s) to the binding head screw terminal(s) prior to insertion of the device in an outlet box.1.2 These performance requirements for wire binding screw terminals are in addition to the requirements for the products covered by the Standard for Attachment Plugs and Receptacles, UL 498, and the Standard for General-Use Snap Switches, UL 20.
This standard covers portable flexible lighting products with a maximum input voltage rating of 120volts to be used in accordance with the National Electrical Code, ANSI/NFPA 70. These products are provided with a power supply cord and are intended for outline and decorative lighting use.1.2 These requirements cover lighting products incorporating non-replaceable series and series/parallel connected lamps enclosed within a flexible polymeric tube or extrusion.1.3 These requirements also cover flexible lighting products used in light sculptures.1.4 These requirements do not cover lighting products with replaceable lamps.1.5 These requirements do not cover the temporary-use, seasonal decorative-lighting products and accessories with a maximum input voltage rating of 120 V that are covered by the Standard for Seasonal and Holiday Decorative Products, UL 588.
1.1 These requirements cover LED equipment that is an integral part of a luminaire or other lighting equipment and which operates in the visible light spectrum between 400 – 700 nm. These requirements also cover the component parts of light emitting diode (LED) equipment, including LED drivers, controllers, arrays, modules, and packages as defined within this standard.
1.1 This standard describes the apparatus, test methods, and formulas to be used in carrying out the tests and calculations required by wire and cable standards. 1.2 Specific acceptance requirements are found in individual product standards. 1.3 Where a test method indicates a “specified” test parameter or condition, the parameter or condition is found in the individual product standard.
Requirements contained in this Standard cover controls of the light-sensitive or presence-sensitive types, or both; for indoor or outdoor service; intended for the control of indoor or outdoor loads up to maximum of 20 A and maximum 347 V; intended for installations on 50 Hz or 60 HZ systems or DC upto 60 V (for US); and DC up to 42.4 V (for Canada); and intended to be installed in accordance with the National Electrical Code (NEC), NFPA 70, the Canadian Electrical Code (CE Code) Part I, CSA C22.2 No0, and NOM 001 SEDE.
1.1 These requirements cover power outlets, with or without integral mounting posts or pedestals, and power outlet fittings for use in accordance with the National Electrical Code, NFPA 70.
1.1 These requirements cover flat-plate photovoltaic modules and panels intended for installation on or integral with buildings, or to be freestanding (that is, not attached to buildings), in accordance with the National Electrical Code, NFPA 70, and Model Building Codes. 1.2 These requirements cover modules and panels intended for use in systems with a maximum system voltage of 1500 V or less. 1.3 These requirements also cover components intended to provide electrical connection to and mounting facilities for flat-plate photovoltaic modules and panels
This part of IEC 61730 specifies and describes the fundamental construction requirements for photovoltaic (PV) modules in order to provide safe electrical and mechanical operation. Specific topics are provided to assess the prevention of electrical shock, fire hazards, and personal injury due to mechanical and environmental stresses. This part of IEC 61730 pertains to the particular requirements of construction. IEC 61730-2 defines the requirements for testing. This International Standard series lays down IEC requirements of terrestrial photovoltaic modules suitable for long-term operation in open-air climates. This standard is intended to apply to all terrestrial flat plate module materials such as crystalline silicon module types as well as thin-film modules. PV modules covered by this standard are limited to a maximum DC system voltage of 1 500 V.
This part of IEC 61730 specifies and describes the fundamental construction requirements for photovoltaic (PV) modules in order to provide safe electrical and mechanical operation. Specific topics are provided to assess the prevention of electrical shock, fire hazards, and personal injury due to mechanical and environmental stresses. This part of IEC 61730 pertains to the particular requirements of construction. IEC 61730-2 defines the requirements for testing. This International Standard series lays down IEC requirements of terrestrial photovoltaic modules suitable for long-term operation in open-air climates. This standard is intended to apply to all terrestrial flat plate module materials such as crystalline silicon module types as well as thin-film modules. PV modules covered by this standard are limited to a maximum DC system voltage of 1 500 V.