BESP 100, Issue 1, November 1, 1996. This procedure describes the process for obtaining a Technical Acceptance Certificate (TAC) for Broadcasting Equipment.
These requirements cover ballasts of the resistance, reactance, and electronic (solid state) types for use with fluorescent lamps involving a potential of 2500 volts or less in accordance with the National Electrical Code, NEPA 70. A fluorescent lamp ballast may be determined by investigation to be acceptable for use, in a fixture or other device, with electric-discharge lamps of other than the fluorescent type. A product that contains features, characteristics, components, materials, or systems new or different from those in use when the standard was developed, and that involves a risk of fire, electric shocks, or injury to persons shall be evaluated using the appropriate additional component and end-product requirements as determined necessary to maintain the level of safety for the user of the product as originally; anticipated by the intent of this standard.
These requirements cover portable, stationary, and fixed uninterruptible power supplies (UPS) rated 600 volts or less ac or dc that are intended for installation in accordance with the National Electrical Code, NFPA 70. During intended operation, the UPS allows the utility to deliver ac and dc power to the connected load through either the power conversion portion of the UPS or a bypass source. The power conversion portion of the UPS consists of a rectifier and an inverter. During periods of power fluctuations, or power outage, or both, the connected load receives ac and dc power from the battery supply and power conversion portion of the UPS.
These requirements cover temporary-use, seasonal decorative-lighting products and accessories with a maximum input voltage rating of 120 V to be used in accordance with the National Electrical Code, ANSI/NFPA 70. Temporary-use is considered to be a period of installation and use not exceeding 90 days. 1.2 These requirements cover factory-assembled seasonal lighting strings with push-in, midget-screw, or miniature-screw lampholders connected in series for across-the-line use or with candelabra- or intermediate-screw lampholders connected in parallel for direct-connection use. These requirements also cover factory-assembled seasonal decorative outfits such as wreaths, stars, light sculptures, crosses, candles or candle sets without lamp shades, products in the shape of, or in resemblance to, Christmas trees with simulated branches and needles, products in the shape of, or in resemblance to, wreaths provided with simulated branches and needles, blow-molded figures or objects, animated figures, tree tops, controllers, tree stands, electric tree poles, and motorized decorative displays. These requirements cover products which are portable and not permanently connected to a power source.
This standard describes the requirements and operational parameters for electrical appliance protectors for use with equipment at normal voltage of 110V, 120V,220V, 240V and a current of up to including 40 A.
This British Standard specifies requirements for the construction dimensions and mechanical and electrical properties of non- armoured polyvinyl chloride (PVC) insulated cables for operation at voltages up to and including 450 V a.c. to earth and 750 V a.c between conductors, intended for electric power lighting and internal wiring.
This standard applies to the labelling of individual packages and cartons of tobacco products intended for retail sale in the Caribbean Community. It specifies the information, the method of display of such information, the wording and presentation of health warnings to be included on the labels of retail packages of tobacco products intended to be sold in the Caribbean Community. But it does not apply to the labelling of cases of such individual packages or cartons, irrespective of sizes, provided the cases are not displayed or used at the point of sale.
1.1 The requirements of this standard cover holders and connectors for electric lamps, including incandescent, fluorescent, and other electric-discharge-type lamps, rated as indicated in Clause 6, to be used in accordance with the Canadian Electrical Code (CEC), Part I, C22.1, and the National Electrical Code (NEC), ANSI/NFPA 70. 1.2 These requirements cover screw lampholders, including those intended to be mounted directly on an outlet-box, lampholders for special uses, lampholders for electric signs, and adapters that convert one lampholder size to another.
These requirements cover FITTINGS for use with cable and conduit intended for installation in accordance with the National Electrical Code, ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part I, CSA C22.1, and the Standard for Electrical Installations, NOM-001-SEDE. 1.2 These requirements cover CONDUIT LOCKNUTS, conduit BUSHINGS, metal stud BUSHINGS, CONDUIT BODIES, and entrance ELBOWS; FITTINGS for electrical metallic tubing, flexible metal conduit, intermediate metal conduit, liquid-tight flexible conduit, rigid metal conduit, and SERVICE-ENTRANCE HEADS; FITTINGS or box clamps referenced from other standards for armored cable, metal-clad cable, aluminum-sheathed cable, mineral-insulated cable, nonmetallic-sheathed cable, service-entrance cable, and tray cable, and submersible FITTINGS; FITTINGS for flexible cord, flexible nonmetallic and metallic tubing, INSULATING BUSHINGS, grips, reducing washers, and NIPPLES.
This standard specifies the requirements for cord sets and power-supply
cords employing molded-on or assembled-on fittings, rated 600 V maximum, and
intended for use in non-hazardous locations in accordance with the National
Electrical Code, ANSI/NFPA 70. It also specifies the requirements for molded-on
general-use attachment plugs and cord connectors etc.