This standard covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80 C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code.. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.
BESP 100, Issue 1, November 1, 1996. This procedure describes the process for obtaining a Technical Acceptance Certificate (TAC) for Broadcasting Equipment.
This standard specifies requirements, including dimensions, materials, finish and selection for sampling for wire nails and cut nails. The following types of wire nails are covered by this standard: (a) Round plain head nails; (b) Round lost head nails; (c) Clout or slate nails; (d) Extra large head clout or felt nails; (e) Convex head roofing nails (chisel or diamond points); (f) Pipe nails (chisel point); (g) Panel pins; (h) Hardboard panel pins (round shank); (i) Hardboard panel pins (square shank); (j) Lath nails; (k) Plasterboard nails (jagged shank); (l) Oval brad head nails; (m) Oval lost head nails; (n) Tile pegs; (o) Tram nails with flat or raised head with chisel point; (p) Spring head twisted shank nails; (q) Square twisted shank flat head nails; (r) Washer head slab nails; (s) Dowels; (t) Annular ringed shank flat head nails; (u) Helical threaded shank flat head nails; and (v) Duplex head nails. The following types of cut nails are covered by this standard: (a) Cut clasp nails; and (b) Cut floor brads. The types of nail covered are illustrated in Tables 1 to 25 and in the corresponding diagrams, Figures 1 to 25.
1.2 Concrete masonry units covered by this specification are made from lightweight or normal weight aggregates, or both.
These requirements cover ballasts of the resistance, reactance, and electronic (solid state) types for use with fluorescent lamps involving a potential of 2500 volts or less in accordance with the National Electrical Code, NEPA 70. A fluorescent lamp ballast may be determined by investigation to be acceptable for use, in a fixture or other device, with electric-discharge lamps of other than the fluorescent type. A product that contains features, characteristics, components, materials, or systems new or different from those in use when the standard was developed, and that involves a risk of fire, electric shocks, or injury to persons shall be evaluated using the appropriate additional component and end-product requirements as determined necessary to maintain the level of safety for the user of the product as originally; anticipated by the intent of this standard.
These requirements cover portable, stationary, and fixed uninterruptible power supplies (UPS) rated 600 volts or less ac or dc that are intended for installation in accordance with the National Electrical Code, NFPA 70. During intended operation, the UPS allows the utility to deliver ac and dc power to the connected load through either the power conversion portion of the UPS or a bypass source. The power conversion portion of the UPS consists of a rectifier and an inverter. During periods of power fluctuations, or power outage, or both, the connected load receives ac and dc power from the battery supply and power conversion portion of the UPS.
This standard specifies the conditions under which ready-mixed concrete shall be made and delivered, and the methods by which the purchaser can specify with his enquiry or order, the properties of the concrete required. It provides a specification for the production and supply of ready-mixed concrete. Methods of specifying ready-mixed concrete for nominal mixes, specified strength mixes and mixes for special purposes, to meet the requirements of standard codes of practice, are covered. It also gives guidance on the data to be provided by the purchaser when ordering ready-mixed concrete, the inspection facilities to be provided by the supplier and the appropriate tests. Routine tests which must be carried out by the supplier and those which are the responsibilities of the purchaser are also included. This standard does not cover the placing, compaction, curing or protection of the concrete after delivery, nor does it apply to materials for lean concrete or similar road care materials.
These requirements cover temporary-use, seasonal decorative-lighting products and accessories with a maximum input voltage rating of 120 V to be used in accordance with the National Electrical Code, ANSI/NFPA 70. Temporary-use is considered to be a period of installation and use not exceeding 90 days. 1.2 These requirements cover factory-assembled seasonal lighting strings with push-in, midget-screw, or miniature-screw lampholders connected in series for across-the-line use or with candelabra- or intermediate-screw lampholders connected in parallel for direct-connection use. These requirements also cover factory-assembled seasonal decorative outfits such as wreaths, stars, light sculptures, crosses, candles or candle sets without lamp shades, products in the shape of, or in resemblance to, Christmas trees with simulated branches and needles, products in the shape of, or in resemblance to, wreaths provided with simulated branches and needles, blow-molded figures or objects, animated figures, tree tops, controllers, tree stands, electric tree poles, and motorized decorative displays. These requirements cover products which are portable and not permanently connected to a power source.
This standard describes the requirements and operational parameters for electrical appliance protectors for use with equipment at normal voltage of 110V, 120V,220V, 240V and a current of up to including 40 A.
This standard specifies requirements for three types of galvanized steel barbed wire. Two classes of galvanized coating, ordinarily and heavily galvanized, are specified.