Standards
This standard gives requirements for the design, location, construction, and maintenance of septic tanks. It includes methods of treatment and disposal of septic tank effluent from domestic sewage. This standard is applicable to individual housing units and institutions where the number of users does not exceed twenty (20) persons. For buildings with more than twenty (20) users an alternative treatment method should be considered with the approval from the relevant authorities.
This British Standard specifies
requirements for sheets of factory-made machine-welded steel fabric for the
reinforcement of concrete, manufactured from ribbed bars conforming to BS
4449:2005, or manufactured from wire conforming to BS 4482 for wrapping fabrics
D49 and D98.
NOTE 1 Where the term “bar” is used in this standard, it includes bar or recoiled product conforming to BS 4449:2005. For clarity only. It can also include wire conforming to BS 4482 for wrapping fabrics only.
This part of ISO/IEC 9314 specifies the Media access control (MAC) , the middle sublayer of the data link layer (DLL) for fiber distributed data interface (FDDI) .FDDI (ISO/IEC 9314) provides a high -bandwidth (100 Mbit/s).general - purpose interconnection among information processing systems, subsystems and peripheral equipment , using fiber optics or other transmission media. FDDI can be configured to support a sustained data transfer rate of at least 80 Mbit/s (10 Mbytes/s). FDDI provides connectivity for many nodes distributed over distances of many kilometers in extent . Certain default parameter values for FDDDI (e.g. timer settings) are calculated on the basis of up to 1000 transmission links or up to 200 km total fiber path length (typically corresponding to 5000 nodes and 100 km of dual fiber cable, respectively), however, the FDDI protocols can support much larger networks by increasing these parameter values.
This part of ISO/IEC 18026 provides an overview of different techniques of security gateways, of components and of different types of security gateway architectures, it also provides guidlines for selection and configuration of security gateways.
This part of ISO/IEC 20000 defines the requirements for a service provider to deliver managed services of an acceptable quality for its customers
This part of ISO/IEC 20000 represents an industry consensus on quality standards for IT service management processes . These service management processes deliver the best possible service to meet a customer's business needs within agreed resource levels, i.e. Service that is professional cost-effective and with risks which are understood and managed.
The fieldbus data link layer provide basic time-critical messaging communication between devices in an automation environment. The purpose of this part of IEC 61158 is to define eight distinct and non- interoperable fieldbus Data link protocols. Each protocol defined in this standard is most most closely related to and lies within the field of application of the corresponding services of IEC 61158-3. the fieldbus data link services definition .
This part of IEC 61850 specifies the specific communication service mappings for the communication between bay and process level and if specifies a mapping on a serial unidirectional multidrop point point to point link in accordance with IEC 60044-8. This part of IEC 61850 specifies a mapping of the abstract service for the transmission of sampled values ( as defined in IEC 61850-7-2 ) on a serial unidirectional multidrop point link in accordance with IEC 60044-8. It applies to the communication between merging units of electronic current (ECT) or voltage-transformers (EVT) and bay devices such as protection relays. If higher requirements on sampling rate. further sampling measured value data sets in addition to the universal data set. inter-bay communication and synchronization apply, these will be covered by IEC 61850-9-2 Figure 1 show the schematics of this interface.
This part of IEC defines the specific communication services mapping (SCSM) for the transmission of sampled values according to the abstract specification in IEC 61850-7-2. The mapping is that of the abstract model on a mixed stack using access to an ISO/IEC 8802-3 link for the transmission of the samples in combination with IEC 61850-8-1.
This part of the ISO/IEC 9314 specifies the Media access control (MAC) the middle sublayer of the data link layer (DLL) for fiber distributed data interface (FDD). FDDI (ISO/IEC 9314) provides a high- bandwidth (100 Mbits) general - purpose interconnection among information processing systems, subsystems and peripheral equipment, using fiber optics or other transmission media. (FDDI can be configured to support a sustained data transfer rate of at least 80 Mbits/s (10 Mbyte/s). FDDI provides connectively for many nodes distributed over distances of many kilometers in extent. Certain default parameter values for FDDI (eg. timer settings) are calculated on the basis of up to 1000 transmission links or up to 200 km total fiber path length (typically corresponding to 500 nodes and 100 km of dual fiber cable, respectively) however, the FDDI protocols can support much larger networks by increasing these parameter values.