Standards
The standards and requirements in this document are the pre-requisite conditions for the issuance of a Technical Acceptance certificate (TAC) for television broadcasting transmitters.
This standards covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.
This standard specifies requirements and dimensions for PVC insulated cables for operation at nominal voltages up to and including 1900 V to armour or earth and 3300 V between conductors.
This standard covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80 C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code.. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.
BESP 100, Issue 1, November 1, 1996. This procedure describes the process for obtaining a Technical Acceptance Certificate (TAC) for Broadcasting Equipment.
This standard specifies the requirements and methods of test for liquid household chorine bleaches.
These requirements cover ballasts of the resistance, reactance, and electronic (solid state) types for use with fluorescent lamps involving a potential of 2500 volts or less in accordance with the National Electrical Code, NEPA 70. A fluorescent lamp ballast may be determined by investigation to be acceptable for use, in a fixture or other device, with electric-discharge lamps of other than the fluorescent type. A product that contains features, characteristics, components, materials, or systems new or different from those in use when the standard was developed, and that involves a risk of fire, electric shocks, or injury to persons shall be evaluated using the appropriate additional component and end-product requirements as determined necessary to maintain the level of safety for the user of the product as originally; anticipated by the intent of this standard.
This standard specifies physical and active ingredient and requirements and methods of test for mosquito coils.
This standard specifies the method for evaluation of the biological efficacy of mosquito coils by the use of glass chamber method. This method provides a satisfactory means of determining the relative efficacy of mosquito coils.