Standards
This international standard gives specific requirements applicable to point-of-care testing and is intended to be used in conjunction with ISO 15189. The requirements of this International standard apply when POCT is carried out in hospital , clinic and by a healthcare organization providing ambulatory care. This International standard can be applied to transcutaneous measurements ,the analysis of expired air, and in vivo monitoring of physiological parameters. Patient self-testing in a home or community setting is excluded, but elements of this International standard can be applicable.
This document specifies general terms and definitions relating to conformity assessment (including the accreditation of conformity assessment bodies) and to the use of conformity assessment to facilitate trade.
The general principles of conformity assessment and a description of the functional approach to conformity assessment are provided in Annex A.
Conformity assessment interacts with other fields such as management systems, metrology, standardization and statistics. The boundaries of conformity assessment are not defined in this document.
ISO/IEC 17000:2004 specifies general terms and definitions relating to conformity assessment, including the accreditation of conformity assessment bodies, and to the use of conformity assessment to facilitate trade. A description of the functional approach to conformity assessment is included as a further aid to understanding among users of conformity assessment, conformity assessment bodies and their accreditation bodies, in both voluntary and regulatory environments.
ISO/IEC 17000:2004 does not set out to provide a vocabulary for all of the concepts that may need to be used in describing particular conformity assessment activities. Terms and definitions are given only where the concept defined would not be understandable from the general language use of the term or where an existing standard definition is not applicable.
This document specifies requirements for safe practices in the medical laboratory (herein after referred to as “the laboratory”).
This International Standard specifies requirements for safe practices in the medical laboratory.
: This standard applies to the transport of petroleum and petroleum products by road tanker wagons licensed by the Guyana Energy Agency.
This standard applies to the transportation of petroleum and petroleum products by bulk transportation carriers licensed by the Guyana Energy Agency. This standard does not apply to road tanker wagons, marine transport and to the transportation liquid petroleum gases (LPG).
This standard specifies materials, construction, performance and testing requirements for low pressure single or two stage regulators for use with liquefied petroleum gas mixtures in vapour phase up to 4.903kN/m2 [50gf/cm2 or 500mm water column (WC)] outlet pressure.
1.1 This Guyana standard covers seven grades of diesel fuel oils suitable for various types of diesel engines. These grades are described as follows: 1.1.1 Grade No. 1-D S15—A special-purpose, light middle distillate fuel for use in diesel engine applications requiring a fuel with 15 ppm sulfur (maximum) and higher volatility than that provided by Grade No. 2-D S15 fuel. 1.1.2 Grade No. 1-D S500—A special-purpose, light middle distillate fuel for use in diesel engine applications requiring a fuel with 500 ppm sulphur (maximum) and higher volatility than that provided by Grade No. 2-D S500 fuel.2 1.1.3 Grade No. 1-D S5000—A special-purpose, light middle distillate fuel for use in diesel engine applications requiring a fuel with 5000 ppm sulphur (maximum) and higher volatility than that provided by Grade No. 2-D S5000 fuels. 1.1.4 Grade No. 2-D S15—A general purpose, middle distillate fuel for use in diesel engine applications requiring a fuel with 15 ppm sulphur (maximum). It is especially suitable for use in applications with conditions of varying speed and load. 1.1.5 Grade No. 2-D S500—A general-purpose, middle distillate fuel for use in diesel engine applications requiring a fuel with 500 ppm sulphur (maximum). It is especially suitable for use in applications with conditions of varying speed and load. 1.1.6 Grade No. 2-D S5000—A general-purpose, middle distillate fuel for use in diesel engine applications requiring a fuel with 5000 ppm sulphur (maximum), especially in conditions of varying speed and load. 1.1.7 Grade No. 4-D—A heavy distillate fuel, or a blend of distillate and residual oil, for use in low- and medium-speed diesel engines in applications involving predominantly constant speed and load.
The main text of this national standard contains a list of these parameters, their units and references to measurement standards. Informative annexes give examples of typical values for these parameters, with the main emphasis on health and safety. In defining the parameters governing composition, physical properties and trace constituents, consideration has also been given to existing natural gases to ensure their continuing viability.
The question of interchangeability is dealt with in Annex A (see Clause A.2).