Standards
This test method is intended to classify fabrics for ironing purposes. It involves ironing of the cloth specimens with a heated aluminium block at increasing temperatures and examination for changes in handle and appearance. The fabrics may then be labelled in accordance with the ironing section of this code in terms of the test temperatures they will withstand as indicated below:
Up to and including 110°C COOL IRON
Up to and including 150°C WARM IRON
Up to and including 200°C HOT IRON
This standard gives recommendations on the serviceability of buildings against vibrations. It covers three recipients of vibrations: a) human occupancy in buildings and on pedestrian bridges; b) the contents of the building; c) the structure of the building. It applies to buildings, pedestrian bridges and walkways found within buildings or connecting them and does not include bridges that carry vehicular traffic, nor the design of foundations or supporting structures of machinery.
This Standard applies to self-contained household refrigerators and freezers designed to be installed and used in residential occupancies in accordance with the Canadian Electrical Code, Part 1, CSA Standard C22.1, and the National Electrical Code, ANSI/NFPA 70.
The requirements cover television equipment intended for household and commercial use on supply circuits in accordance with the National Electrical Code, NFPA 70.
This standards covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.
This standard specifies requirements and dimensions for PVC insulated cables for operation at nominal voltages up to and including 1900 V to armour or earth and 3300 V between conductors.
This standard describes the properties of mercury the nature of hazards associated with it and essential information on its storage, handling packing , labelling disposal of waste and personal preventive measures.
This standard covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80 C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code.. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.