Standards
This standard specifies the requirements for zinc-coated, steel chain-link fence fabric (zinc-coated either before or after weaving) and poly (vinyl chloride) coated, zinc-coated steel chain-link fence fabric.
This standard specifies requirements for circular-cross-section seamless polypropylene (PP) pipes made from homopolymer polypropylene (PP-H), block copolymer polypropylene (PP-R) or random copolymer polypropylene with modified crystalline structure and elevated temperature resistance (PP-RCT).
This regional standard specifies requirements for high density polyethylene garbage badge which are normally used for the disposal of domestic and commercial waste. It includes requirements and test methods for impact resistance bag dimensions, burst resistance, heat seal integrity and leakage. This standard does not apply to bag intended for the disposal of industrial, biological or medical waste.
This standard gives requirements for the design, location, construction, and maintenance of septic tanks. It includes methods of treatment and disposal of septic tank effluent from domestic sewage. This standard is applicable to individual housing units and institutions where the number of users does not exceed twenty (20) persons. For buildings with more than twenty (20) users an alternative treatment method should be considered with the approval from the relevant authorities.
This Regional
Standard
specifies requirements
for
hydraulic cements used
primarily
in the construction industry. It includes requirements for compressive strength, physical properties, chemical properties, packaging, labelling and the means of
determining conformance to these requirements. It does not apply to Portland and blended cement. This standard does not apply to
ASTM C150M Type IV cement.
This standard covers flat-bottomed water storage tanks of circular cross-section manufactured from unreinforced polyethylene by the process of rotational moulding. Included are requirements for physical characteristics, dimensions, materials performance, testing marking and labelling.
These specifications apply to tanks intended for:
(a) The storage of potable water at normal atmospheric pressure;
(b) Installation and use at environmental or service temperatures such that the material of tank remains between 15 °C and 80°C; and
(c) Vertical, above- ground installation on fixed, flat, fully- supporting bases.
The scope of the International Building Code® (IBC®) includes all buildings except detached one- and two-family dwellings and townhouses up to three stories. For the most current adoptions details go to International Code Adoptions
The 2018 IBC contains many important changes such as:
- Accessory storage spaces of any size are now permitted to be classified as part of the occupancy to which they are accessory.
- New code sections have been introduced addressing medical gas systems and higher education laboratories.
- Use of fire walls to create separate buildings is now limited to only the determination of permissible types of construction based on allowable building area and height.
- Where an elevator hoistway door opens into a fire-resistance-rated corridor, the opening must be protected in a manner to address smoke intrusion into the hoistway.
- The occupant load factor for business uses has been revised to one occupant per 150 square feet.
- Live loads on decks and balconies increase the deck live load to one and one-half times the live load of the area served.
- The minimum lateral load that fire walls are required to resist is five pounds per square foot.
- Wind speed maps updated, including maps for the state of Hawaii. Terminology describing wind speeds has changed again with ultimate design wind speeds now called basic design wind speeds.
- Site soil coefficients now correspond to the newest generation of ground motion attenuation equations (seismic values).
- Five-foot tall wood trusses requiring permanent bracing must have a periodic special inspection to verify that the required bracing has been installed.
- New alternative fastener schedule for construction of mechanically laminated decking is added giving equivalent power-driven fasteners for the 20-penny nail.
- Solid sawn lumber header and girder spans for the exterior bearing walls reduce span lengths to allow #2 Southern Pine design values.