Standards
This standards covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.
This Japanese Standard specifies the seat belt assembles for automobiles, hereinafter referred to as the “Seat belt” to accommodate one adult and to be fitted principally to forward facing seat for the purpose of protecting the wearer from injury in the event of a traffic accident.
This standard specifies legal metrology requirements for labelled packaged commodities with constant nominal content and subject to international trade. It also covers sampling plans for net content verification of goods declared in units of mass or volume.
1.2 Concrete masonry units covered by this specification are made from lightweight or normal weight aggregates, or both.
This standard specifies performance requirements for hollow load-bearing concrete masonry units made from Portland cement, water and mineral aggregates with or without the inclusion of other materials. It covers three weight classifications of the concrete masonry units: (a) normal weight; (b) medium weight; and (c) lightweight.
This standard specifies requirements for hollow non-load-bearing concrete masonry units made from portland cement, water and mineral aggregates with or without the inclusion of other materials. It covers three weight classifications of the concrete masonry units: (a) Normal weight; (b) Medium weight; and (c) Light weight. It also covers the sampling and testing of hollow non-load-bearing concrete masonry units for compressive strength, absorption, weight, moisture content and dimensions. It does not cover blocks intended solely for decorative purposes.
These requirements cover portable, stationary, and fixed uninterruptible power supplies (UPS) rated 600 volts or less ac or dc that are intended for installation in accordance with the National Electrical Code, NFPA 70. During intended operation, the UPS allows the utility to deliver ac and dc power to the connected load through either the power conversion portion of the UPS or a bypass source. The power conversion portion of the UPS consists of a rectifier and an inverter. During periods of power fluctuations, or power outage, or both, the connected load receives ac and dc power from the battery supply and power conversion portion of the UPS.
This standard specifies the requirements and the methods of test for ice-cream and related products, with the incorporation of fruits, nuts or chocolate either singly or in combination.
This standard specifies physical and active ingredient and requirements and methods of test for mosquito coils.
This standard specifies the method for evaluation of the biological efficacy of mosquito coils by the use of glass chamber method. This method provides a satisfactory means of determining the relative efficacy of mosquito coils.