Standards
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
This standard describes the requirements and operational parameters for electrical appliance protectors for use with equipment at normal voltage of 110V, 120V,220V, 240V and a current of up to including 40 A.
This British Standard specifies requirements for the construction dimensions and mechanical and electrical properties of non- armoured polyvinyl chloride (PVC) insulated cables for operation at voltages up to and including 450 V a.c. to earth and 750 V a.c between conductors, intended for electric power lighting and internal wiring.
This standard applies to the products known as achar, amchar and kuchela which are prepared from edible fruits such as green or unripe mangoes (Mangifera indica), golden apple (Pommecythere spp.), june plum (Spondias spp.), tamarind (Tamarindua indica) and chalta elephant fruit (Dillenia indica), as the predominant ingredients and blended with spices and additives prior to packaging
This document is applicable to packaged natural coconut water which is offered for sale and consumption. It applies only to coconut water which has been packaged in its natural state without the use of additives.
This standard applies to packaged natural coconut water, as defined in clause 3, which is offered for consumption. It only applies to coconut water which has been packaged in its natural state without the use of additives.
This document specifies the procedure for marking containers or labels for fertilizers.
This document is applicable to all fertilizers in containers or bulk.
This International Standard specifies the procedure for marking containers or labels for fertilizers, where national legislation permits.
It is applicable to all fertilizers in containers.
1.1 The requirements of this standard cover holders and connectors for electric lamps, including incandescent, fluorescent, and other electric-discharge-type lamps, rated as indicated in Clause 6, to be used in accordance with the Canadian Electrical Code (CEC), Part I, C22.1, and the National Electrical Code (NEC), ANSI/NFPA 70. 1.2 These requirements cover screw lampholders, including those intended to be mounted directly on an outlet-box, lampholders for special uses, lampholders for electric signs, and adapters that convert one lampholder size to another.
These requirements cover FITTINGS for use with cable and conduit intended for installation in accordance with the National Electrical Code, ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part I, CSA C22.1, and the Standard for Electrical Installations, NOM-001-SEDE. 1.2 These requirements cover CONDUIT LOCKNUTS, conduit BUSHINGS, metal stud BUSHINGS, CONDUIT BODIES, and entrance ELBOWS; FITTINGS for electrical metallic tubing, flexible metal conduit, intermediate metal conduit, liquid-tight flexible conduit, rigid metal conduit, and SERVICE-ENTRANCE HEADS; FITTINGS or box clamps referenced from other standards for armored cable, metal-clad cable, aluminum-sheathed cable, mineral-insulated cable, nonmetallic-sheathed cable, service-entrance cable, and tray cable, and submersible FITTINGS; FITTINGS for flexible cord, flexible nonmetallic and metallic tubing, INSULATING BUSHINGS, grips, reducing washers, and NIPPLES.