— Energy efficiency ratio (EER);
— Coefficiency of peformance (COP).
This standard specifies the information to be included on labels of all pesticides, in any form, including aerosol insecticides that are destined to be applied by end-users.
This standard does not apply to pesticides:
a) which are used as human pharmaceuticals; or
b) utilised in an industrial setting, that is, active ingredients, bulk pesticide formulations destined for reformulation, repackaging or disposal or other pesticide formulation components.
This standard specifies a system of designating the sizes of clothing, the control dimensions on which the size designation is based and the method of indicating these dimensions on the label.
This standard also specifies body dimensions related to each size, as stated in Appendix A.
This standard specifies the general labelling requirements for electrical equipment, fittings and electrical appliances and their detachable heating element (s) if any, offered for sale in Guyana.
This Guyana Standard shall be applied to all electrical equipment, fittings and electrical appliances and should therefore be a standard for a particular products. It shall be applied in conjunction with the labelling requirements of this standard.
The scope of the International Building Code® (IBC®) includes all buildings except detached one- and two-family dwellings and townhouses up to three stories. For the most current adoptions details go to International Code Adoptions
The 2018 IBC contains many important changes such as:
- Accessory storage spaces of any size are now permitted to be classified as part of the occupancy to which they are accessory.
- New code sections have been introduced addressing medical gas systems and higher education laboratories.
- Use of fire walls to create separate buildings is now limited to only the determination of permissible types of construction based on allowable building area and height.
- Where an elevator hoistway door opens into a fire-resistance-rated corridor, the opening must be protected in a manner to address smoke intrusion into the hoistway.
- The occupant load factor for business uses has been revised to one occupant per 150 square feet.
- Live loads on decks and balconies increase the deck live load to one and one-half times the live load of the area served.
- The minimum lateral load that fire walls are required to resist is five pounds per square foot.
- Wind speed maps updated, including maps for the state of Hawaii. Terminology describing wind speeds has changed again with ultimate design wind speeds now called basic design wind speeds.
- Site soil coefficients now correspond to the newest generation of ground motion attenuation equations (seismic values).
- Five-foot tall wood trusses requiring permanent bracing must have a periodic special inspection to verify that the required bracing has been installed.
- New alternative fastener schedule for construction of mechanically laminated decking is added giving equivalent power-driven fasteners for the 20-penny nail.
- Solid sawn lumber header and girder spans for the exterior bearing walls reduce span lengths to allow #2 Southern Pine design values.