Standards
This standard applies to packaged natural coconut water, as defined in clause 3, which is offered for consumption. It only applies to coconut water which has been packaged in its natural state without the use of additives.
This document specifies the procedure for marking containers or labels for fertilizers.
This document is applicable to all fertilizers in containers or bulk.
This International Standard specifies the procedure for marking containers or labels for fertilizers, where national legislation permits.
It is applicable to all fertilizers in containers.
This standard gives requirements for the design, location, construction, and maintenance of septic tanks. It includes methods of treatment and disposal of septic tank effluent from domestic sewage. This standard is applicable to individual housing units and institutions where the number of users does not exceed twenty (20) persons. For buildings with more than twenty (20) users an alternative treatment method should be considered with the approval from the relevant authorities.
This CARICOM Regional Standard specifies requirements and methods of test for pasta products made from semolina, durum flour, wheat flour, farina flour or any suitable wheat flour. This standard is applicable to pasta classified as macaroni, spaghetti, vermicelli, noodles and egg noodles. This standard also applies to pasta products used in preparing other foods or included in packages of ingredients that are prepared for retail sale. EXAMPLE Pasta used in canned soups, soup mixes, macaroni and cheese dinners. This CARICOM Regional Standard is not applicable to Asian/Oriental style noodles including chowmein or chaomein and to other food in forms resembling pasta products made from rice, beans or cereals other than wheat.
This British Standard specifies
requirements for sheets of factory-made machine-welded steel fabric for the
reinforcement of concrete, manufactured from ribbed bars conforming to BS
4449:2005, or manufactured from wire conforming to BS 4482 for wrapping fabrics
D49 and D98.
NOTE 1 Where the term “bar” is used in this standard, it includes bar or recoiled product conforming to BS 4449:2005. For clarity only. It can also include wire conforming to BS 4482 for wrapping fabrics only.
This CARICOM Regional Standard provides requirements for implementation and maintenance of a food safety and sanitation programme for tourism establishments.
While these requirements may be applicable to other establishments where food is prepared and served, for the purposes of this document the standard applies to all food premises which are part of the tourism establishment.
This standard applies to structures, and food transport vehicles and associated equipment, fixtures and fittings used by the food business in the tourism establishment.
This standard does not apply to organisations such as government ministries, regulatory departments and agencies, associations and statutory bodies that do not provide a tourism related service.
This CARICOM Regional Standard specifies requirements for a water treatment management and efficiency programme for tourism establishments including:
a) the definition of terms common to water service providers;
b) basic requirements for drinking water supply and treatment systems;
c) guidelines for objectives, service assessment criteria and related performance indicators;
d) benchmarks for measuring performance of water management, treatment and efficiency.
This standard does not apply to:
a) organisations such as government ministries, regulatory departments and agencies, associations and statutory bodies that do not provide a tourism related service; and
b) objectives set forth by the national water authority and other relevant agencies which are to be achieved through implementation of national standards and compliance obligations.
The purpose of this Standard is to provide criteria for the safe erection, use, and inspection of access scaffold (as covered in CSA S269.2 and engineered systems) and for the training of erectors and users of such equipment.
1.2 Subjects addressed
This Standard applies to the erection, use, and inspection of access scaffold that is
a) supported on a surface;
b) hung from multiple points, but is not capable of moving vertically or horizontally; or
c) mounted on wheels.
This Standard addresses key hazards, including fall hazards, structural instability, platform failures, and material handling problems.
Note: In this Standard, the term erection refers to the assembling, altering, or dismantling of a scaffold.
While this Standard applies to scaffold as defined in Clause 3, this Standard is not limited to scaffold used solely for the purpose of construction, maintenance, or repair operations.
1.3 Equipment not covered
This Standard does not apply to the following:
a) falsework and formwork for construction purposes, as covered in CSA S269.1;
b) suspended access equipment, as covered in CSA Z91 and CAN/CSA-Z271;
c) elevating work platforms, as covered in CAN/CSA-B354.6, CAN/CSA-B354.7, and CAN/CSA-B354.8;
d) manual or powered mast-climbing work platforms, such as a pump jack scaffold or equipment covered in CSA B354.9, CSA B354.10, and CSA B354.11;
e) centre-pole scaffolds; and
f) appliances or accessories attached to scaffold.
1.4 Terminology
In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; may is used to express an option or that which is permissible within the limits of the standard; and can is used to express possibility or capability.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
1.5 Measurement
The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
This standard can be purchased via the Canadian Standards Association website https://www.csagroup.org/store/product/Z797-18/
This code of practice gives recommendations and guidance on the use of IRATA International rope access methods, including training, to provide a safe system of work. It is intended for use by IRATA International members, IRATA International rope access technicians, national or regional enforcement agencies, safety officers and those who commission rope access work, e.g. building contractors; multi-national oil and gas companies; the renewable energy sector. This code of practice is applicable to the use of IRATA International rope access methods for industrial purposes, i.e. for access to buildings, other structures (on or offshore) or natural features, such as cliff faces, where ropes are used as the primary means of access, egress or support and as the primary means of protection against a fall. This code of practice is not intended to apply to the use of rope-based access methods for leisure activities, arboriculture, general steeplejack methods or emergency personal evacuation systems, or to the use of rope-based access (line rescue) techniques by fire brigades and other emergency services for rescue work or for rescue training. NOTE Throughout this code of practice, the term rope access is intended to mean rope access for industrial purposes, unless otherwise stated.
This International Code of Practice for Industrial Rope Access Systems’ is freely available on the IRATA website to anyone who wishes to access it. Please see the following links:
- The IRATA website – irata.org
- IRATA freely available publications - Publications | IRATA International
- Access to the document (ICOP) - ‘IRATA International Code of Practice for Industrial Rope Access’