Standards
This publication:
- Provides technical guidance on the storage and dispensing of petroleum products including petrol, diesel, autogas (also known as LPG) and biofuels (blends of petrol or diesel containing up to 10 % biomass derived component), used as fuels for motor vehicles, primarily at filling stations to which the general public have access.
- Covers civil, mechanical, hydraulic and electrical installation issues for the planning, design, construction, commissioning, modification, maintenance and decommissioning of filling stations.
- Provides information aimed at minimizing the risks from fire and explosion, to safety, health and to the environment.
- Describes good practice and certain legal requirements, particularly those applicable in the UK.
- Is primarily intended to be applicable to both new sites and existing sites that are modified/refurbished. The guidance should also be useful in providing a benchmark to assist the duty-holder to undertake periodic review of their risk assessment(s) required under specific legislation applying to the facilities.
- Provides general principles that may be applicable to other types of installation where fuels are stored and dispensed for non-retail use.
This standard applies to the storage and handling of portable containers used for storage of Liquefied Petroleum Gases (LPG) and to the transportation of these containers.
This standard does not cover the storage, handling and transport of ammonia cylinders.
This document specifies the requirements for the audit and certification of a food safety management system (FSMS) complying with the requirements given in ISO 22000 (or other specified FSMS requirements). It also provides the necessary information and confidence to customers about the way certification of their suppliers has been granted.
Certification of FSMS is a third-party conformity assessment activity (as described in ISO/IEC 17000:2020, 4.3), and bodies performing this activity are third-party conformity assessment bodies.
NOTE 1 In this document, the terms “product” and “service” are used separately (in contrast with the definition of “product” given in ISO/IEC 17000).
NOTE 2 This document can be used as a criteria document for the accreditation or peer assessment of certification bodies which seek to be recognized as being competent to certify that an
FSMS complies with ISO 22000 or other sets of specified FSMS requirements. It is also intended to be used as a criteria document by regulatory authorities and industry consortia which engage in direct recognition of certification bodies to certify that an FSMS complies with ISO 22000. Some of its requirements can also be useful to other parties involved in the conformity assessment of such certification bodies, and in the conformity assessment of bodies that undertake to certify the compliance of FSMS with criteria additional to, or other than, those in ISO 22000. FSMS certification does not attest to the safety or fitness of the products of an organization within the food chain. However, an FSMS requires an organization to meet all applicable food-safety-related statutory and regulatory requirements through its management system.
NOTE 3 Certification of an FSMS according to ISO 22000 is a management system certification, not a product certification. Other FSMS users can use the concepts and requirements of this document provided that the requirements are adapted as necessary.
: This standard applies to the transport of petroleum and petroleum products by road tanker wagons licensed by the Guyana Energy Agency.
This standard applies to the transportation of petroleum and petroleum products by bulk transportation carriers licensed by the Guyana Energy Agency. This standard does not apply to road tanker wagons, marine transport and to the transportation liquid petroleum gases (LPG).
This standard specifies materials, construction, performance and testing requirements for low pressure single or two stage regulators for use with liquefied petroleum gas mixtures in vapour phase up to 4.903kN/m2 [50gf/cm2 or 500mm water column (WC)] outlet pressure.