Standards
This publication:
- Provides technical guidance on the storage and dispensing of petroleum products including petrol, diesel, autogas (also known as LPG) and biofuels (blends of petrol or diesel containing up to 10 % biomass derived component), used as fuels for motor vehicles, primarily at filling stations to which the general public have access.
- Covers civil, mechanical, hydraulic and electrical installation issues for the planning, design, construction, commissioning, modification, maintenance and decommissioning of filling stations.
- Provides information aimed at minimizing the risks from fire and explosion, to safety, health and to the environment.
- Describes good practice and certain legal requirements, particularly those applicable in the UK.
- Is primarily intended to be applicable to both new sites and existing sites that are modified/refurbished. The guidance should also be useful in providing a benchmark to assist the duty-holder to undertake periodic review of their risk assessment(s) required under specific legislation applying to the facilities.
- Provides general principles that may be applicable to other types of installation where fuels are stored and dispensed for non-retail use.
This document applies to single storey houses up to 7.62 m x 12.19 m (25 ft x 40 ft) plan, with hollow block masonry or timber framed walls, and timber framed or concrete roofs. It provides the user with the technical information to supervise the construction of a safe and durable house, and to facilitate checks on whether a safe and durable house is being built.
This document does not include construction details for utilities (including plumbing, electrical, communications, security, and natural gas. It also does not include construction details for solid brick masonry.
This document specifies the general requirements and tests for safety devices for fuel gases and oxygen or compressed air which do not incorporate a flame (flashback) arrestor used downstream of manifold, cylinder and/or pipeline outlet regulators, and upstream of blowpipes for welding, cutting and allied processes. This document does not specify the location of these devices in the gas system. This document is not applicable to safety devices which incorporate a flame arrestor, covered by ISO 5175-1.
This specification covers hollow and solid (see 5.3 and 5.4) concrete masonry units made from hydraulic cement, water, and mineral aggregates with or without the inclusion of other materials. There are three classes of concrete masonry units: Normal Weight, Medium Weight, and Lightweight. These units are suitable for both load bearing and non-load bearing applications. This standard covers hollow blocks from sizes of 3in. (76.2mm) to 8 in. (203.2mm).
Concrete masonry units covered by this specification are made from lightweight or normal weight aggregates, or both.
This part of ISO 15489 provides guidelines on managing records 1 of originating organizations, public or private, for internal and external clients. All the elements outlined in this part of ISO 15489 are recommended to ensure that adequate records according to the principles and elements outlined in this part ISO 15489 are provided in ISO /TR 15489-2 (Guidelines).
This part of ISO 15489 is an implementation guide to ISO 15489-1 -1 for use by record management professional and those charged with management records in their organizations. It provides one methodology that will facilitates the implementation of ISO 15489-1 in all organization that have a need to manage their records. It gives an overview of the processes and factors to consider in organization wishing to comply with ISO 15489-1.
This part of ISO/IEC 9314 specifies the Media access control (MAC) , the middle sublayer of the data link layer (DLL) for fiber distributed data interface (FDDI) .FDDI (ISO/IEC 9314) provides a high -bandwidth (100 Mbit/s).general - purpose interconnection among information processing systems, subsystems and peripheral equipment , using fiber optics or other transmission media. FDDI can be configured to support a sustained data transfer rate of at least 80 Mbit/s (10 Mbytes/s). FDDI provides connectivity for many nodes distributed over distances of many kilometers in extent . Certain default parameter values for FDDDI (e.g. timer settings) are calculated on the basis of up to 1000 transmission links or up to 200 km total fiber path length (typically corresponding to 5000 nodes and 100 km of dual fiber cable, respectively), however, the FDDI protocols can support much larger networks by increasing these parameter values.
This part of ISO/IEC 18026 provides an overview of different techniques of security gateways, of components and of different types of security gateway architectures, it also provides guidlines for selection and configuration of security gateways.
This part of ISO/IEC 20000 defines the requirements for a service provider to deliver managed services of an acceptable quality for its customers
This part of ISO/IEC 20000 represents an industry consensus on quality standards for IT service management processes . These service management processes deliver the best possible service to meet a customer's business needs within agreed resource levels, i.e. Service that is professional cost-effective and with risks which are understood and managed.