Standards
This Code of Practice specifies the requirements for concrete and block masonry used in structures or buildings.
This Standard applies to self-contained household refrigerators and freezers designed to be installed and used in residential occupancies in accordance with the Canadian Electrical Code, Part 1, CSA Standard C22.1, and the National Electrical Code, ANSI/NFPA 70.
The requirements cover television equipment intended for household and commercial use on supply circuits in accordance with the National Electrical Code, NFPA 70.
This standard specifies requirements for hollow blocks made from fired clay. The standard covers the general quality, dimensions and strength of the blocks.
This standards covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.
This standard specifies requirements and dimensions for PVC insulated cables for operation at nominal voltages up to and including 1900 V to armour or earth and 3300 V between conductors.
This standard covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80 C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code.. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.
This standard specifies requirements, including dimensions, materials, finish and selection for sampling for wire nails and cut nails. The following types of wire nails are covered by this standard: (a) Round plain head nails; (b) Round lost head nails; (c) Clout or slate nails; (d) Extra large head clout or felt nails; (e) Convex head roofing nails (chisel or diamond points); (f) Pipe nails (chisel point); (g) Panel pins; (h) Hardboard panel pins (round shank); (i) Hardboard panel pins (square shank); (j) Lath nails; (k) Plasterboard nails (jagged shank); (l) Oval brad head nails; (m) Oval lost head nails; (n) Tile pegs; (o) Tram nails with flat or raised head with chisel point; (p) Spring head twisted shank nails; (q) Square twisted shank flat head nails; (r) Washer head slab nails; (s) Dowels; (t) Annular ringed shank flat head nails; (u) Helical threaded shank flat head nails; and (v) Duplex head nails. The following types of cut nails are covered by this standard: (a) Cut clasp nails; and (b) Cut floor brads. The types of nail covered are illustrated in Tables 1 to 25 and in the corresponding diagrams, Figures 1 to 25.
1.2 Concrete masonry units covered by this specification are made from lightweight or normal weight aggregates, or both.