This publication:
- Provides technical guidance on the storage and dispensing of petroleum products including petrol, diesel, autogas (also known as LPG) and biofuels (blends of petrol or diesel containing up to 10 % biomass derived component), used as fuels for motor vehicles, primarily at filling stations to which the general public have access.
- Covers civil, mechanical, hydraulic and electrical installation issues for the planning, design, construction, commissioning, modification, maintenance and decommissioning of filling stations.
- Provides information aimed at minimizing the risks from fire and explosion, to safety, health and to the environment.
- Describes good practice and certain legal requirements, particularly those applicable in the UK.
- Is primarily intended to be applicable to both new sites and existing sites that are modified/refurbished. The guidance should also be useful in providing a benchmark to assist the duty-holder to undertake periodic review of their risk assessment(s) required under specific legislation applying to the facilities.
- Provides general principles that may be applicable to other types of installation where fuels are stored and dispensed for non-retail use.
This document applies to single storey houses up to 7.62 m x 12.19 m (25 ft x 40 ft) plan, with hollow block masonry or timber framed walls, and timber framed or concrete roofs. It provides the user with the technical information to supervise the construction of a safe and durable house, and to facilitate checks on whether a safe and durable house is being built.
This document does not include construction details for utilities (including plumbing, electrical, communications, security, and natural gas. It also does not include construction details for solid brick masonry.
This specification covers hollow and solid (see 5.3 and 5.4) concrete masonry units made from hydraulic cement, water, and mineral aggregates with or without the inclusion of other materials. There are three classes of concrete masonry units: Normal Weight, Medium Weight, and Lightweight. These units are suitable for both load bearing and non-load bearing applications. This standard covers hollow blocks from sizes of 3in. (76.2mm) to 8 in. (203.2mm).
Concrete masonry units covered by this specification are made from lightweight or normal weight aggregates, or both.
This part of ISO 15489 provides guidelines on managing records 1 of originating organizations, public or private, for internal and external clients. All the elements outlined in this part of ISO 15489 are recommended to ensure that adequate records according to the principles and elements outlined in this part ISO 15489 are provided in ISO /TR 15489-2 (Guidelines).
This part of ISO 15489 is an implementation guide to ISO 15489-1 -1 for use by record management professional and those charged with management records in their organizations. It provides one methodology that will facilitates the implementation of ISO 15489-1 in all organization that have a need to manage their records. It gives an overview of the processes and factors to consider in organization wishing to comply with ISO 15489-1.
This CARICOM Regional Standard provides requirements for implementation and maintenance of a food safety and sanitation programme for tourism establishments.
While these requirements may be applicable to other establishments where food is prepared and served, for the purposes of this document the standard applies to all food premises which are part of the tourism establishment.
This standard applies to structures, and food transport vehicles and associated equipment, fixtures and fittings used by the food business in the tourism establishment.
This standard does not apply to organisations such as government ministries, regulatory departments and agencies, associations and statutory bodies that do not provide a tourism related service.
This CARICOM Regional Standard specifies requirements for a water treatment management and efficiency programme for tourism establishments including:
a) the definition of terms common to water service providers;
b) basic requirements for drinking water supply and treatment systems;
c) guidelines for objectives, service assessment criteria and related performance indicators;
d) benchmarks for measuring performance of water management, treatment and efficiency.
This standard does not apply to:
a) organisations such as government ministries, regulatory departments and agencies, associations and statutory bodies that do not provide a tourism related service; and
b) objectives set forth by the national water authority and other relevant agencies which are to be achieved through implementation of national standards and compliance obligations.
This CARICOM Regional Standard provides requirements for the implementation and maintenance of a solid waste management programme for tourism establishments.
This standard does not apply to:
a) organisations such as government
ministries, regulatory departments and agencies, associations and statutory
bodies that do not provide a tourism related service; and
b) solid solutions, solids in
solutions and non-solid waste.
EXAMPLE Solid solutions include construction steel, brass and amalgam waste which may arise from construction, plumbing, dentistry and other activities.
This part of ISO/IEC 9314 specifies the Media access control (MAC) , the middle sublayer of the data link layer (DLL) for fiber distributed data interface (FDDI) .FDDI (ISO/IEC 9314) provides a high -bandwidth (100 Mbit/s).general - purpose interconnection among information processing systems, subsystems and peripheral equipment , using fiber optics or other transmission media. FDDI can be configured to support a sustained data transfer rate of at least 80 Mbit/s (10 Mbytes/s). FDDI provides connectivity for many nodes distributed over distances of many kilometers in extent . Certain default parameter values for FDDDI (e.g. timer settings) are calculated on the basis of up to 1000 transmission links or up to 200 km total fiber path length (typically corresponding to 5000 nodes and 100 km of dual fiber cable, respectively), however, the FDDI protocols can support much larger networks by increasing these parameter values.
This part of ISO/IEC 18026 provides an overview of different techniques of security gateways, of components and of different types of security gateway architectures, it also provides guidlines for selection and configuration of security gateways.