Standards
This Building Code can be purchased via https://codes.iccsafe.org/content/CREEBC2018
This standard outlines a code of safety for chemical laboratories.
1 Scope
1.1 This standard outlines a code of safety for chemical laboratories.
1.2 The standard outlines:
(a) general rules of conduct concerning safety;
(b) details for fire emergency and rescue procedures;
(c) general laboratory techniques.
1.3 This standard does not cover hazards relating to radioactive substances.
This Code of Practice specifies the requirements for concrete and block masonry used in structures or buildings.
This document applies to single storey houses up to 7.62 m x 12.19 m (25 ft x 40 ft) plan, with hollow block masonry or timber framed walls, and timber framed or concrete roofs. It provides the user with the technical information to supervise the construction of a safe and durable house, and to facilitate checks on whether a safe and durable house is being built.
This document does not include construction details for utilities (including plumbing, electrical, communications, security, and natural gas. It also does not include construction details for solid brick masonry.
This standard specifies requirements for the operation of laboratories and is applicable to all laboratories regardless of the number of personnel or the extent of the scope of testing activities.
This standard is for use by laboratories in developing their quality, administrative and technical systems that govern their operations. Any party may use this standard when confirming or recognising the competence of laboratories.
This standard specifies requirements for the operation of testing and/or calibration laboratories. It is applicable to all laboratories regardless of the number of personnel or the extent of the scope of testing activities.
This standard specifies requirements for hollow blocks made from fired clay. The standard covers the general quality, dimensions and strength of the blocks.
This standard specifies requirements, including dimensions, materials, finish and selection for sampling for wire nails and cut nails. The following types of wire nails are covered by this standard: (a) Round plain head nails; (b) Round lost head nails; (c) Clout or slate nails; (d) Extra large head clout or felt nails; (e) Convex head roofing nails (chisel or diamond points); (f) Pipe nails (chisel point); (g) Panel pins; (h) Hardboard panel pins (round shank); (i) Hardboard panel pins (square shank); (j) Lath nails; (k) Plasterboard nails (jagged shank); (l) Oval brad head nails; (m) Oval lost head nails; (n) Tile pegs; (o) Tram nails with flat or raised head with chisel point; (p) Spring head twisted shank nails; (q) Square twisted shank flat head nails; (r) Washer head slab nails; (s) Dowels; (t) Annular ringed shank flat head nails; (u) Helical threaded shank flat head nails; and (v) Duplex head nails. The following types of cut nails are covered by this standard: (a) Cut clasp nails; and (b) Cut floor brads. The types of nail covered are illustrated in Tables 1 to 25 and in the corresponding diagrams, Figures 1 to 25.