Standards
This Code of Practice specifies the requirements for concrete and block masonry used in structures or buildings.
This Code of Practice specifies requirements for poultry meat which have not yet been treated in any way to ensure their preservation, except that it has been chilled or frozen and is intended for human consumption, whether by direct sale or through further processing. This Code of Practice applies to all establishments in which poultry is slaughtered, packed, or otherwise handled in the course of preparation, and all establishments in which poultry cuts and parts are processed, packed, or otherwise handled in the course of preparation. It also applies to conditions of transport from the establishment. This Code of Practice does not cover requirements for poultry rearing.
This document applies to single storey houses up to 7.62 m x 12.19 m (25 ft x 40 ft) plan, with hollow block masonry or timber framed walls, and timber framed or concrete roofs. It provides the user with the technical information to supervise the construction of a safe and durable house, and to facilitate checks on whether a safe and durable house is being built.
This document does not include construction details for utilities (including plumbing, electrical, communications, security, and natural gas. It also does not include construction details for solid brick masonry.
This standard establishes specification for nutrient requirements in the rations fed to poultry. It provides guidance on Good Manufacturing Practices for the production of poultry feeds and Good on Farming Feeding Practices. It applies to the production and use of all materials designed for poultry feed and feed ingredients at all levels, whether produced industrially or on farm.
This standard describes exhaust emission requirements for all new domestic and commercial vehicles which have been registered in Guyana for the first time after December 31, 1997. This standard also describes exhaust emission requirements, measurement methods and measurement equipment for all vehicles, which are imported into Guyana after December 31, 1997. All imported vehicles would be required to conform to exhaust emission limits specified in the standard. Accordingly, the exhaust emission limits must be fully documented and certified by the suppliers/manufacturers, from the country of origin.
This standard establishes the basic principles for carrying out vibration measurement and processing data, with regard to evaluating vibration effects on buildings. The evaluations of the effects of building vibration are primarily directed at structural response, and include appropriate analytical methods where the frequency, duration and amplitude can be defined. It only deals with the measurement of structural vibration and excludes the measurement of airborne sound pressure and other pressure fluctuations.
This standard provides general guidance on methods of carrying out penetrant inspection
on materials and components both during manufacture and in service. It does not
deal with acceptance or rejection. Penetrant inspection is used to locate
discontinuities, such as laps, folds, cracks, porosity and fissures, which are
open to the surface of a material or component. Penetrant techniques can be
used on materials irrespective of their physical properties, provided that the surface
is normally non-absorbent and compatible with the penetrant process.
This standard provides general guidance on the verification procedures to be applied when
carrying out penetrant inspection, in accordance with ISO 3452. These tests are intended to ensure that the
penetrant system is functioning correctly and that there has been no harmful
deterioration of the process materials during service. Generally, the frequency
of checking penetrant materials and black light sources will depend on the
frequency and conditions of usage. Specific and maximum intervals should be recommended
by the manufacturer.
.
This standard specifies the minimum requirements for industrial illuminators
used for viewing radiographs.