Standards
This publication:
- Provides technical guidance on the storage and dispensing of petroleum products including petrol, diesel, autogas (also known as LPG) and biofuels (blends of petrol or diesel containing up to 10 % biomass derived component), used as fuels for motor vehicles, primarily at filling stations to which the general public have access.
- Covers civil, mechanical, hydraulic and electrical installation issues for the planning, design, construction, commissioning, modification, maintenance and decommissioning of filling stations.
- Provides information aimed at minimizing the risks from fire and explosion, to safety, health and to the environment.
- Describes good practice and certain legal requirements, particularly those applicable in the UK.
- Is primarily intended to be applicable to both new sites and existing sites that are modified/refurbished. The guidance should also be useful in providing a benchmark to assist the duty-holder to undertake periodic review of their risk assessment(s) required under specific legislation applying to the facilities.
- Provides general principles that may be applicable to other types of installation where fuels are stored and dispensed for non-retail use.
This document applies to single storey houses up to 7.62 m x 12.19 m (25 ft x 40 ft) plan, with hollow block masonry or timber framed walls, and timber framed or concrete roofs. It provides the user with the technical information to supervise the construction of a safe and durable house, and to facilitate checks on whether a safe and durable house is being built.
This document does not include construction details for utilities (including plumbing, electrical, communications, security, and natural gas. It also does not include construction details for solid brick masonry.
This specification covers hollow and solid (see 5.3 and 5.4) concrete masonry units made from hydraulic cement, water, and mineral aggregates with or without the inclusion of other materials. There are three classes of concrete masonry units: Normal Weight, Medium Weight, and Lightweight. These units are suitable for both load bearing and non-load bearing applications. This standard covers hollow blocks from sizes of 3in. (76.2mm) to 8 in. (203.2mm).
Concrete masonry units covered by this specification are made from lightweight or normal weight aggregates, or both.
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
This standard specifies the requirements and methods of test for urea, fertiliser grade.
This International Standard specifies requirements for establishing, implementing, maintaining and improving an energy management system, whose purpose is to enable an organization to follow a systemic approach in achieving continual improvement of energy performance, including energy efficiency, energy use and consumption.
These requirements cover products which are molded of insulating material and are molded of insulating material and are intended to cover the outlet slots of receptacles having 1-15R and 5-15R configurations in accordance with Wiring Devices - Dimensional Specifications, ANSI/NEMA WD6.
a) Self-ballasted compact fluorescent lamps (CFL) of voltages > 50 V;
b) Integrated light-emitting diode lamps (LEDi) for stable operations, intended for domestic and similar general lighting purposes, having a:
1) rated power up to 60 W;
2) rated voltage of > 50 V a.c up to 250 V a.c.
This standard does not apply to semi-integrated (LEDsi) and non-integrated (LEDni) light-emitting diode lamps.
— Energy efficiency ratio (EER);
— Coefficiency of peformance (COP).
This document specifies requirements for and gives guidance on the application of life cycle costing to create value for the development activities and operations associated with drilling, exploitation, processing and transport of petroleum, petrochemical and natural gas resources. This document covers facilities and associated activities within different business categories (upstream, midstream, downstream and petrochemical).
The extent of planning and management depends on the magnitude of the costs involved, the potential value that can be created and the life cycle phase. It also provides the means of identifying cost drivers and provides a cost-control framework for these cost drivers, allowing effective cost control and optimization over the entire life of an asset.