This Code of Practice specifies the requirements for concrete and block masonry used in structures or buildings.
This document applies to single storey houses up to 7.62 m x 12.19 m (25 ft x 40 ft) plan, with hollow block masonry or timber framed walls, and timber framed or concrete roofs. It provides the user with the technical information to supervise the construction of a safe and durable house, and to facilitate checks on whether a safe and durable house is being built.
This document does not include construction details for utilities (including plumbing, electrical, communications, security, and natural gas. It also does not include construction details for solid brick masonry.
This standard specifies the general labelling requirements for electrical equipment, fittings and electrical appliances and their detachable heating element(s) if any, offered for sale in Guyana.
This Guyana Standard shall be applied to all electrical equipment, fittings and electrical appliances and should therefore be a standard for a particular product. It shall be applied in conjunction with the labelling requirements of this standard.
This standard specifies the general labelling requirements for Electrical Equipment, Fittings and household electrical appliances and their detachable heating element(s) if any, offered for sale in Guyana. This Guyana Standard shall be applied for all Electrical Equipment, Fittings and household electrical appliance, should there be a standard for a particular product it shall be applied in conjunction with the labelling requirements of this standard.
This Standard applies to self-contained household refrigerators and freezers designed to be installed and used in residential occupancies in accordance with the Canadian Electrical Code, Part 1, CSA Standard C22.1, and the National Electrical Code, ANSI/NFPA 70.
The requirements cover television equipment intended for household and commercial use on supply circuits in accordance with the National Electrical Code, NFPA 70.
This standard specifies requirements for hollow blocks made from fired clay. The standard covers the general quality, dimensions and strength of the blocks.
This standards covers thermoplastic and rubber tapes for use as electrical insulation at not more than 600 V and at 80C (176 F) and lower temperatures on joints and splices in wires and cables in accordance with the National Electrical Code. It is intended that rubber tape on a joint or splice be mechanically protected by a covering such as friction tape . Thermoplastic tape is acceptable without the additional mechanical protection.
This standard specifies requirements and dimensions for PVC insulated cables for operation at nominal voltages up to and including 1900 V to armour or earth and 3300 V between conductors.